Power Generation of Grid-Connected Photovoltaic Systems (PVS) and its Impact in the Electricity Bill.

Los Sistemas Fotovoltaicos (SFV) Interconectados a la red eléctrica reducen el consumo de energía de la red, siendo una alternativa en tarifas donde el cargo es únicamente por este concepto. Para usuarios en tarifa Doméstica de Alto Consumo (DAC) la reducción de la demanda de la energía de la red tiene un alto impacto en la facturación de energía, sin embargo, se han encontrado errores técnicos de instalación que no permiten al sistema generar la máxima potencia. Se presenta un análisis histórico del consumo y generación de energía de un sistema SFV interconectado de 5 kWp en tarifa 1 (DAC); se encontró que inyecta 30 % de la capacidad total instalada. Se muestran los datos de generación en las condiciones instaladas y los datos al aplicar las recomendaciones al sistema SFV logrando aumentar la generación, la inyección de energía a la red y mejorando el impacto sobre la facturación.

Ler mais

Power Generation of Grid-Connected Photovoltaic Systems (PVS) and its Impact in the Electricity Bill.

  • DOI: 10.22533/at.ed.3172115108

  • Palavras-chave: Sistema interconectado (SFV) a la red, tarifa eléctrica, demanda máxima.

  • Keywords: Grid-connected photovoltaic systems (PVS), electrical rate, maximum demand.

  • Abstract:

    Grid-connected photovoltaic systems (PVS) reduce energy consumption from the network, being an alternative in rates where the charge is just for this concept. For users in domestic high consumption rate (DAC by its acronym in Spanish) the reduction in energy demand from the network has a high impact in the electricity billing, however, it has been found technical installation errors that do not allow the system to generate the maximum power. This work presents the analysis of the historical record of consumption and generation of a grid-connected PVS of 5kWp in rate 1 (DAC) which supplies the 30% of the total installed capacity. It is shown the data of power generation with the installed conditions and the data when recommendations were applied in the PVS installation; it increasing power generation and injection of energy and so the reduction in the electrical bill was achieved.

  • Número de páginas: 10

  • Virgilio Alfonso Murillo-Rodríguez
  • Raul Quiroz-Martínez
  • Filiberto Briseño-Aguilar
  • Juan Carlos Gutiérrez-Villegas
Fale conosco Whatsapp