This paper presents the results of tests to calculate the integral curve and saturation curve of fission counters installed in the RP-10 Nuclear Reactor, which allows the polarization voltage of the detector and the discrimination level of the start-up amplifier to be determined.

Ler mais

Estimación del voltaje de discriminación y polarización de Cámara de fisión en las Cadenas de Arranque del Reactor Nuclear RP10

  • DOI: https://doi.org/10.22533/at.ed.153222529045

  • Palavras-chave: Integral Curve, Saturation Curve, Polarization Voltage, Discrimination Level.

  • Keywords: Integral Curve, Saturation Curve, Polarization Voltage, Discrimination Level.

  • Abstract:

    This paper presents the results of tests to calculate the integral curve and saturation curve of fission counters installed in the RP-10 Nuclear Reactor, which allows the polarization voltage of the detector and the discrimination level of the start-up amplifier to be determined.